Description of folders: * Basic simulation: The standard configuration. Mol concentration of MeOH (x_MeOH) is controlled using air flow and total flow is controlled using MeOH flow. Air flow reaches its maximum and you loose control of x_MeOH * Compressor_test: loop with the compressor. you can have a set point for the air flow. the static part of the compressor is the compressor map. * Open loop tests: Similar to Basic simulation_dynamic_mixer. This is to "play" more with the model, without messing up with it. There might be slight differences in tuning. * Others_not used: Other files. I tried to implement a motor for the dynamics of the compressor. However, there are some sizing parameters that have to be defined and I decided to not continue investing time in that. * TPM_change simulation: The difference wrt "Basic simulation_dynamic_mixer" is that the TPM is switched. Now, (x_MeOH) is controlled using MeOH flow and the total flow is controlled using m_air When air flow reaches its maximum, you keep control of x_MeOH, but loose control of m_tot. * Valve_test loop with valve, including actuator.